I am running appcmd from "%windir%\system32\inetsrv" Please find a sample output below: C:\Windows\System32\inetsrv>appcmd add backup "UnableRestoreList20110118" BACKUP object "UnableRestoreList20110118" added C:\Windows\System32\inetsrv>appcmd list backup ERROR ( hresult:80070781, message:Command execution failed. I'm a bit paranoid about using the new IIS Manager in IIS7 to > > modify the Default Web Site. > > > Running appcmd with "Default Web Site" as the Center trace between two pads Does トイレ refer to the British "toilet" or the American "toilet"? Both of these applications are set to use the DefaultAppPool application pool. check over here

May 05, 2011 06:48 PM|victor_cavendish|LINK I'm still experiencing this on my Dev environment. This enables you to quickly execute complex management tasks without writing application code. Unable to Restore or List ba... This means that there is a ton of help available.

Appcmd.exe Set Config

Introduction IS7.0 provides a new command-line tool, AppCmd.exe, to configure and query objects on your Web server, and to return output in text or XML. To display effective configuration for particular url level, use the LIST command of the Config object as follows: %systemroot%\system32\inetsrv\APPCMD list config /section:SectionName Where is the configuration path at which To get a more fully functioning IIS site, use the following two commands: AppCmd add site /name:ddsite /id:99 /bindings:http/*:81: /physicalPath:C:\ddsite AppCmd add app /site.name:DDSite /path:/ddapp /physicalPath:C:\sites\ddsite 3) Listing objects that meet

Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! Why put a warning sticker over the warning on this product? Depalindromize this string! Appcmd Set Config ["site_name"] /section:system.webserver/directorybrowse /enabled:true Most collections require only one key.

The commit parameter can be set to one of the following: (omitted) — default; write configuration at the level for which it is set url — same as default; write configuration Appcmd Iis 8 On Jan 18, 11:34 am, "clintonG" wrote: > "David Wang" wrote in message > > news:[email protected] groups.com... > On Jan 17, 8:33 pm, "clintonG" wrote: > > > I just saw this bird outside my apartment. http://stackoverflow.com/questions/24938391/appcmd-exe-isapicgirestriction-error-cannot-find-requested-collection-element Tip explains how to get manually created replication connection objects in an Active Directory Forest...

AppCmd provides this capability through its commit parameter. Appcmd Start Apppool Thank you. –Filip Sep 4 '14 at 16:56 add a comment| up vote 5 down vote For IIS users looking for the standard version (non Express): cd %windir%\system32\inetsrv share|improve this answer Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the First Skills to Learn for Mountaineering Wait...

Appcmd Iis 8

In short, anything goes -- it all depends on the application. https://blogs.iis.net/deanc/configuration-editor-an-admin-s-best-friend This hierarchy is in contrast to IIS 6.0 where a Web site can contain a mix of virtual directories and applications, and applications are just specially marked virtual directories. Appcmd.exe Set Config Where do airports use 3-bar VASI for the visual glideslope? Appcmd.exe Iis 6 When I removed the quotes, I could restore.

By default, AppCmd uses a compact output format: %systemroot%\system32\inetsrv\APPCMD list sites SITE "Default Web Site" (id:1,bindings:HTTP/*:80:,state:Started) SITE "Site1" (id:2,bindings:http/*:81:,state:Started) SITE "Site2" (id:3,bindings:http/*:82:,state:Stopped) In this output format, each object instance is on check my blog Notice the number of properties on the application pool object; the full output is not shown here. Exporting data to other tools. The section parameter specifies the configuration section you would like to read. Appcmd List

The physicalPath parameter specifies the physical location of the virtual directory. Application Pool An application pool specifies a group of settings for the worker processes that perform request processing for the applications in that application pool. Typically, each of these commands would be used with an object type that you are asking AppCmd.exe to perform the requested function on. this content I had to comment out the httpHandlers and httpModules etc.

Manage Your Profile | Site Feedback Site Feedback x Tell us about your experience... Cannot Find Site Object With Identifier more hot questions question feed default about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Determine maximum frequency of input signal to make system LTI Storage of a material that passes through non-living matter If I receive written permission to use content from a paper without

By Mike VolodarskyMichael Volodarsky is the CTO of LeanServer, developing cutting edge performance and scalability technologies for some of the largest web sites on the Microsoft web platform.

The name of the file cannot be resolved by the system. ) C:\Windows\System32\inetsrv>appcmd restore backup "UnableRestoreList20110118" ERROR ( message:Cannot find BACKUP object with identifier "UnableRestoreList2011 0118". ) C:\Windows\System32\inetsrv>appcmd delete backup "UnableRestoreList20110118" Add-in salt to injury? To set a property on a collection element, specify the particular collection element to edit by using a collection indexer expression within the element path notation. Appcmd List Wp To name a few - with a GUI you cannot do repetitive tasks quickly (like with a Windows Desktop Shortcut) nor can you use output from one AppCmd.exe output and send

I learned about using the following command... > > %systemroot%\system32\inetsrv\APPCMD.EXE migrate config "Default Web > Site/YourApp" > > I think I know what /YourApp implies but I don't know what I How can I check that the voltage output from this voltage divider is 2.25V? The web site will not just load and I learn I have to run appcmd= > > > to > > > migrate to IIS7. http://knowaretech.com/cannot-find/appcmd-cannot-find-site-object.html Below, you see me backing up my IIS configuration then listing out what backups were available after that.

I open the web site in Visual > Studio 2008 for development. > > But I still don't understand the difference between a web site and an > application. > > pingingEnabled:"true"... Executing the tool a large number of times when performing a large number of operations (for example creating 10,000 sites) may be slow due to the overhead of process creation and In this article, I will explain what this tool is, how to use it, and how to perform common IIS administrative tasks such as creating new sites, stopping/starting services, and viewing

Let me show you how. When listing sites or application pools, the state is displayed in the default output. asked 2 years ago viewed 692 times active 1 year ago Related 304ASP.NET MVC on IIS 7.5697error: Unable to find vcvarsall.bat288An ASP.NET setting has been detected that does not apply in Once done, I went back to the Config Editor window and hit “Generate Script”, and here’s what I got: Now, anyone see a problem with that?

It didn’t occur to me that the name would be an issue when using appcmd until I went to use the sample command that Config Editor gave me. Other references: http://forums.iis.net/t/1166823.aspx http://forums.iis.net/p/1160389/1915020.aspx#1915020 Thanks, Victor Reply victor_caven... 10 Posts Re: APPCMD list/restore Backup fails... Wang > // > > You are correct David, I did want to move my "webapp" into the root of the > Default Web Site and access it ashttp://MyWebsiteinstead > ofhttp://MyWebsite/MyAppand Volume Serial Number is 7006-D360 Directory of C:\Windows\System32\inetsrv\backup 01/20/2011 11:57 AM

. 01/20/2011 11:57 AM .. 01/20/2011 11:57 AM sampleBackup 0 File(s) 0 bytes 3 Dir(s) 122,288,406,528 bytes

These tools often work best when each data item of interest is located on a separate line. Any suggestions. All AppCmd objects support the same standard syntax for setting properties: APPCMD SET [ /property:value ]* First, let's display the applications available on the machine: %systemroot%\system32\inetsrv\APPCMD list apps APP all bindings on port 443)?3Kernel-mode Authentication: 401 errors when accessing site from remote machines1Anonymous Authentication / 403 - Forbidden: Access is denied6Moving a site from IIs6 to IIS7.55appcmd command to

Volume Serial Number is 7006-D360 Directory of C:\Windows\System32\inetsrv\backup\sampleBackup 01/20/2011 11:57 AM

. 01/20/2011 11:57 AM .. 01/06/2011 03:20 PM 19,836 administration.config 01/19/2011 05:44 PM 217,697 applicationHost.config 01/10/2011 09:38 AM It omitted, changes will be applied at the server level, to be inherited by all URLs. Yes No Tell us more Flash Newsletter | Contact Us | Privacy Statement | Terms of Use | Trademarks | © 2016 Microsoft © 2016 Microsoft

Why is this C++ code faster than my hand-written assembly for testing the Collatz conjecture?